Pilot Feasibility Trial of the SafeLM Supraglottic Airway (SGA)

Part of paid clinical trials in Houston, Texas.

Sponsor
The University of Texas Health Science Center, Houston
Study ID
NCT05989880
Status
Recruiting

Conditions

  • Anesthesia

Eligibility Criteria

Sex
ALL
Age
18 Years - N/A
Healthy Volunteers
Not accepted

Interventions

  • SafeLM as a supraglottic airway device with video capability — DEVICE
    The device will be inserted using the video capability and used as a primary airway device for the duration of the surgical procedure. Once the device is in place, the cuff will be inflated with the recommended volume of air to ensure an adequate seal around the laryngeal opening. The position of the device will be confirmed by observing the video image of the glottis on the monitor. The adequacy of ventilation and oxygenation will be assessed by monitoring the patient's end-tidal CO2, pulse oximetry, and clinical signs of effective ventilation. Leak and cuff pressure will be assessed. The device will be removed at the end of the surgical procedure or if there are any signs of device malfunction, airway obstruction, or inadequate ventilation.
  • SafeLM as a supraglottic airway device without video capability — DEVICE
    The device will be blindly inserted without using the video capability and used as a primary airway device for the duration of the surgical procedure. Once the device is in place, the cuff will be inflated with the recommended volume of air to ensure an adequate seal around the laryngeal opening. The position of the device will be confirmed by observing the video image of the glottis on the monitor. The adequacy of ventilation and oxygenation will be assessed by monitoring the patient's end-tidal CO2, pulse oximetry, and clinical signs of effective ventilation. Leak and cuff pressure will be assessed. The video capability of the device will be used to assess the accuracy of placement after the fact. The device will be removed at the end of the surgical procedure or if there are any signs of device malfunction, airway obstruction, or inadequate ventilation.
  • SafeLM as a conduit for intubation using an endotracheal tube with video capability — DEVICE
    The device will be inserted, and an endotracheal tube will be advanced through the device under direct visualization using the video capability of the device. Once the device is in place, the cuff will be inflated with the recommended volume of air to ensure an adequate seal around the laryngeal opening. The endotracheal tube will be introduced through the working channel of the SafeLM under direct visualization using the video capability of the device. The endotracheal tube will be advanced into the trachea, and the position will be confirmed by end-tidal carbon dioxide (EtCO2) detection and chest auscultation. The cuff of the endotracheal tube will be inflated, and mechanical ventilation will be resumed. The SafeLM device will be removed, and the position of the endotracheal tube will be confirmed once again.
  • SafeLM as a conduit for intubation using a bougie with video capability — DEVICE
    The device will be inserted. Once the device is in place, the cuff will be inflated with the recommended volume of air to ensure an adequate seal around the laryngeal opening.The position of the device will be confirmed by observing the video image of the glottis on the monitor. The video camera on the SafeLM will be turned on to visualize the vocal cords.A standard airway bougie will be introduced through the working channel of the SafeLM under direct visualization using the video capability of the device.The SafeLM device will be removed, and an appropriately sized endotracheal tube will be advanced into the trachea. If a bougie is not able to be inserted into the tracheal under direct visualization, direct insertion of an endotracheal tube into the trachea will be attempted, followed by flexible scope intubation.

Study Details

The purpose of this study is to assess the feasibility of SafeLM as a primary airway device and as a conduit for intubation with and without the use of a bougie

Key Dates

Start date
Sep 19, 2023
Status verified
Dec 2024
Primary completion
Oct 2, 2025
Completion
Dec 2, 2025

Study Design

Enrollment
60 participants (estimated)
Allocation
NON_RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT

Arms

  • Experimental: SafeLM as a supraglottic airway device with video capability
  • Experimental: SafeLM as a supraglottic airway device without video capability
  • Experimental: SafeLM as a conduit for intubation using an endotracheal tube with video capability
  • Experimental: SafeLM as a conduit for intubation using a bougie with video capability

Primary Outcome Measure

Intubation success rate [ Time Frame: at the time of intubation ]