Pediatric Positive End Expiratory Pressure (PEEP) Titration Using Electrical Impedence Tomography (EIT)

Part of paid clinical trials in Los Angeles, California.

Sponsor
Children's Hospital Los Angeles
Study ID
NCT06684119
Status
Recruiting

Conditions

  • Pediatric Acute Respiratory Distress Syndrome

Eligibility Criteria

Sex
ALL
Age
0 Years - 18 Years
Healthy Volunteers
Not accepted

Interventions

  • Electrical Impedance Tomography positive end-expiratory pressure titration — DEVICE
    A PEEP titration will occur for the patient with the PEEP increased by 2 cm H2O every 2 minutes until a maximum PEEP of 20 or three steps (+ 6 cm H2O) above the set clinical PEEP. The PEEP will then be decreased by 2 cmH2O every 2 minutes until a minimum PEEP of 6 cmH2O or three steps (- 6 cm H2O) below their clinical PEEP.

Study Details

The goal of this clinical trial is to perform a PEEP titration protocol and use EIT to identify the optimal PEEP at which lung overdistention and collapse are most effectively balanced. The primary and secondary aims of the study are as follows: Identify the difference between the optimal PEEP recommended by EIT metrics and the current guideline recommended approach to identifying optimal PEEP in PARDS. There will be a statistically significant difference in the recommended optimal PEEP identified using the EIT PEEP titration tool and that of the PEEP/FiO2 grid recommendations. Determine the difference in physiologic metrics between EIT optimal PEEP and the PEEP/FiO2 recommended PEEP. Participants will undergoing EIT monitoring while being subjected to PEEP titration protocol.

Key Dates

Start date
Dec 10, 2024
Status verified
Dec 2024
Primary completion
Jan 1, 2027
Completion
Jul 1, 2027

Study Design

Enrollment
60 participants (estimated)
Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
TREATMENT

Arms

  • Experimental: Electrical Impedance Tomography positive end-expiratory pressure
    Patients will be monitored using Electrical Impedance Tomography and the positive end-expiratory pressure titration tool as their positive end-expiratory pressure is adjusted according to a step wise positive end-expiratory pressure titration protocol.

Primary Outcome Measure

The absolute difference between the electrical impedence tomography (EIT) recommended PEEP and the PEEP recommended by the PEEP/fraction of inspired oxygen (FiO2) grid. [ Time Frame: Day 1 ]

Central Contacts