Rapid Inflation/Deflation Compared With Prolonged High-Pressure Balloon Inflation
Part of paid clinical trials in Little Rock, Arkansas.
- Sponsor
- Central Arkansas Veterans Healthcare System
- Study ID
- NCT01952873
- Status
- Not Yet Recruiting
Notify me when recruiting opens
Save your spot on the interest list for this study. We'll keep your details with this study so our team can follow up when recruiting opens.
Add your contact details and location so we can keep your interest tied to this study.
Conditions
- Coronary Artery Disease
- Coronary Stent Occlusion
Eligibility Criteria
- Sex
- ALL
- Age
- 19 Years - N/A
- Healthy Volunteers
- Not accepted
Interventions
- Prolonged inflation — OTHERProlonged inflation will be performed at high pressure(16 atm)and maintained for 30 sec with \<0.3 atm drop during that period.
- Rapid inflation — OTHERThe rapid inflation method will consist of reaching an operator determined high-pressure (16 atm) with the stent-deployment balloon and maintaining it the duration of time determined by the operator but \<30 sec if the balloon is fully inflated and longer only if the balloon requires a longer duration to become fully inflated.
Study Details
It is universally accepted that high-pressure balloon inflation is required to most effectively deploy a coronary balloon-expandable stent. However, there is not consensus nor are there any guidelines regarding the method of balloon inflation, particularly the duration of inflation. Underexpansion and strut malapposition after stent deployment are among the most powerful predictors for adverse vessel outcomes. High-pressure inflation for stent deployment is effective to optimally expand the stent, but unlike in vitro testing in air, there are poorly distensible plaque elements that may not instantaneously yield to the balloon pressure. However, these elements may ultimately yield to prolonged inflation. Most clinical interventional cardiologists inflate for a relatively short period (15-30 sec). The investigators have noted that when balloon pressure is maintained at a certain pressure level it tends to decrease over time, and may require 60-180 or more seconds to maintain pressure stability. This finding implies that plaque elements are yielding slowly over time to the increased pressure, thus increasing expansion, and suggests that a prolonged inflation until balloon pressure stabilizes is more effective than a rapid inflation/deflation sequence to fully expand and appose the stent to the vessel wall. At present there is no consensus on stent deployment strategy. It is our hypothesis that prolonged inflation is superior to the more commonly used strategy of rapid inflation/deflation. Optimal coherence tomography (OCT), a novel technology that measures near-infrared light reflections and translates them into a 2D image, has an axial resolution nearly 10-times that of intravascular ultrasound (IVUS). Thus it is possible to examine the extent of stent malposition and stent expansion using this modality. The current randomized trial tests the hypothesis that prolonged balloon inflation until a stable balloon pressure is maintained is more effective than a rapid inflation/deflation sequence when performed to the same balloon inflation pressure.
Key Dates
- Start date
- Jan 31, 2027
- Status verified
- Aug 2024
- Primary completion
- Dec 31, 2028
- Completion
- Dec 31, 2028
Study Design
- Enrollment
- 40 participants (estimated)
- Allocation
- RANDOMIZED
- Intervention model
- PARALLEL
- Primary purpose
- TREATMENT
Arms
- Active Comparator: RapidThe rapid inflation method will consist of reaching an operator determined high-pressure (16 atm) with the stent-deployment balloon and maintaining it the duration of time determined by the operator but \<30 sec if the balloon is fully inflated and longer only if the balloon requires a longer duration to become fully inflated.
- Experimental: ProlongedProlonged inflation will be performed at high pressure(16 atm)and maintained for 30 sec with \<0.3 atm drop during that period.
Primary Outcome Measure
Number of unopposed stent struts [ Time Frame: Day 1 Within first hour after after stent deployment ]
Central Contacts
- Kristin Miller, RN501-257-5893
Locations (1)
| Facility | City | State | ZIP | Site coordinators |
|---|---|---|---|---|
| John L. McClellan Memorial Veterans Hospital | Little Rock | Arkansas | 72205 | Barry F Uretsky, MD (PRINCIPAL_INVESTIGATOR) |
Find similar trials in Little Rock, AR
Related Studies
- Product Surveillance RegistryRecruiting · Medtronic · Birmingham, Alabama
- Distal Evaluation of Functional Performance with Intravascular Sensors to Assess the Narrowing Effect: Guided Physiologic StentingEnrolling By Invitation · Philips Clinical & Medical Affairs Global · Birmingham, Alabama
- SELUTION 4 De Novo Small Vessel IDE TrialRecruiting · M.A. Med Alliance S.A. · Jonesboro, Arkansas
- CTSN Embolic Protection TrialRecruiting · Icahn School of Medicine at Mount Sinai · North Little Rock, Arkansas