Rapid Inflation/Deflation Compared With Prolonged High-Pressure Balloon Inflation

Part of paid clinical trials in Little Rock, Arkansas.

Sponsor
Central Arkansas Veterans Healthcare System
Study ID
NCT01952873
Status
Not Yet Recruiting

Notify me when recruiting opens

Save your spot on the interest list for this study. We'll keep your details with this study so our team can follow up when recruiting opens.

Not yet recruiting

Add your contact details and location so we can keep your interest tied to this study.

Conditions

  • Coronary Artery Disease
  • Coronary Stent Occlusion

Eligibility Criteria

Sex
ALL
Age
19 Years - N/A
Healthy Volunteers
Not accepted

Interventions

  • Prolonged inflation — OTHER
    Prolonged inflation will be performed at high pressure(16 atm)and maintained for 30 sec with \<0.3 atm drop during that period.
  • Rapid inflation — OTHER
    The rapid inflation method will consist of reaching an operator determined high-pressure (16 atm) with the stent-deployment balloon and maintaining it the duration of time determined by the operator but \<30 sec if the balloon is fully inflated and longer only if the balloon requires a longer duration to become fully inflated.

Study Details

It is universally accepted that high-pressure balloon inflation is required to most effectively deploy a coronary balloon-expandable stent. However, there is not consensus nor are there any guidelines regarding the method of balloon inflation, particularly the duration of inflation. Underexpansion and strut malapposition after stent deployment are among the most powerful predictors for adverse vessel outcomes. High-pressure inflation for stent deployment is effective to optimally expand the stent, but unlike in vitro testing in air, there are poorly distensible plaque elements that may not instantaneously yield to the balloon pressure. However, these elements may ultimately yield to prolonged inflation. Most clinical interventional cardiologists inflate for a relatively short period (15-30 sec). The investigators have noted that when balloon pressure is maintained at a certain pressure level it tends to decrease over time, and may require 60-180 or more seconds to maintain pressure stability. This finding implies that plaque elements are yielding slowly over time to the increased pressure, thus increasing expansion, and suggests that a prolonged inflation until balloon pressure stabilizes is more effective than a rapid inflation/deflation sequence to fully expand and appose the stent to the vessel wall. At present there is no consensus on stent deployment strategy. It is our hypothesis that prolonged inflation is superior to the more commonly used strategy of rapid inflation/deflation. Optimal coherence tomography (OCT), a novel technology that measures near-infrared light reflections and translates them into a 2D image, has an axial resolution nearly 10-times that of intravascular ultrasound (IVUS). Thus it is possible to examine the extent of stent malposition and stent expansion using this modality. The current randomized trial tests the hypothesis that prolonged balloon inflation until a stable balloon pressure is maintained is more effective than a rapid inflation/deflation sequence when performed to the same balloon inflation pressure.

Key Dates

Start date
Jan 31, 2027
Status verified
Aug 2024
Primary completion
Dec 31, 2028
Completion
Dec 31, 2028

Study Design

Enrollment
40 participants (estimated)
Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT

Arms

  • Active Comparator: Rapid
    The rapid inflation method will consist of reaching an operator determined high-pressure (16 atm) with the stent-deployment balloon and maintaining it the duration of time determined by the operator but \<30 sec if the balloon is fully inflated and longer only if the balloon requires a longer duration to become fully inflated.
  • Experimental: Prolonged
    Prolonged inflation will be performed at high pressure(16 atm)and maintained for 30 sec with \<0.3 atm drop during that period.

Primary Outcome Measure

Number of unopposed stent struts [ Time Frame: Day 1 Within first hour after after stent deployment ]